Data Center Design
The SuperNova network has been designed to accommodate clients demanding the highest quality network performance. There is a central focus on redundancy allowing our network to rapidly self-heal failures without interruptions to connectivity. At SuperNova, we own our infrastructure.
tier-1 premium bandwith
Providing
the highest quality
Internet connectivity
and performance is our
top priority. We have
selected premium Tier-1
bandwidth providers,
ensuring minimal latency
and fast connections to
all points of the global
internet. We are proud
to feature direct
connectivity with AT&T,
Verizon, Sprint, Savvis
and Level3. Our
aggregate connectivity
reaches an astounding
8,500+ networks just a
single network away from
our uplinks.
security on-site
Datacenter
access is strictly
limited to technical
staff. Electronic
security systems control
data center access and
are accompanied by a
full compliment of
motion detecting
security cameras which
monitor the entire
facility. Our Data
Center facility external
walls are reinforced
poured concrete. We are
a fully managed
facility, which means we
have level 3 technicians
on site 24 hours per
day, allowing incident
response times to be
kept to a minimum.
Our average support request phone call is answered within 20 seconds, with an average electronic support response time of 10 minutes.
power system
Our
power systems feature
extensive fault
tolerance and resilience
at every layer. Incoming
service is routed
underground to a
dedicated on-site
transformer. This system
routes to our automatic
transfer switch which
monitors power quality,
and automatically
transfers to our
emergency generators in
the event they are
needed. Each facility is
also protected by one or
more uninterruptible
Power Supplies (UPS),
featuring redundant
battery cabinets and
full maintenance bypass
cabinets allowing for
service and upgrades
without interruption of
power to our servers.

Liebert Precision power distribution units handle final power transformation and distribution to racks, ensuring clean consistent power to data center equipment.
Each facility has multiple emergency generators waiting on standby, featuring over 24 hours of autonomous runtime before requiring refueling. Each generator is test run at least once a week to ensure they are ready in the event they are needed.
cooling
Environmental
processing systems
include redundant
Liebert Precision 22 ton
up flow air conditioning
units. Temperature and
humidity are precisely
regulated year round to
ensure optimal equipment
reliability. Each unit
contains independent
compressors and cooling
loops to further enhance
fault tolerance and
reliability. Air
filtration systems
actively remove foreign
particulates from
circulation and cycle
the entire data center
air supply in a matter
of minutes.